Table 2-a
Indications of the charge indicator lamp
Charge
indicator
lamp
(RED /
BLUE /
GREEN /
PURPLE)
Before
charging
Blinks
(RED)
Lights for 0.5 seconds. Does not light
for 0.5 seconds.
(o for 0.5 seconds)
Plugged into power source
While
charging
Blinks
(BLUE)
Lights for 0.5 seconds. Does not light
for 1 second.
(o for 1 second)
Battery capacity at less than
50%
Blinks
(BLUE)
Lights for 1 second. Does not light for
0.5 seconds.
(o for 0.5 seconds)
Battery capacity at less than
80%
Lights
(BLUE)
Lights continuously
Battery capacity at more than
80%
Charging
complete
Lights
(GREEN)
Lights continuously
(Continuous buzzer sound: about
6 seconds)
Overheat
standby
Blinks
(RED)
Lights for 0.3 seconds. Does not light
for 0.3 seconds.
(o for 0.3 seconds)
Battery overheated. Unable
to charge. (Charging will
commence when battery cools)
Charging
impossible
Flickers
(PURPLE)
Lights for 0.1 seconds. Does not light
for 0.1 seconds.
(o for 0.1 seconds)
(Intermittent buzzer sound: about
2 seconds)
Malfunction in the battery or the
charger
Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 2-b, according to the condition of the charger or
the rechargeable battery.