4
- All Other Markets:
NOTE:
(*) Measure burner operating pressure at Burner Operating Pressure test point on gas
control valve, with burner operating at 'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be
adjusted, apart from when converting between gasses, if required.
Standard models can only be converted between Nat. Gas, LP Gas and Butane, but not
Town Gas.
Refer to Gas Conversion and Specifications' section in this manual for further details.
Gas supply connection point is located 152mm from left hand side, 36mm from rear of appliance,
124mm from floor and is entered from beneath appliance. An optional rear connection is available.
Connection is
3
/
4
BSP male.
A cold water supply must be connected to water inlet connection (R
1
/
2
" BSP), located 50mm from
LH side, 556mm from rear and 151mm from floor. Water connection should be plumbed in, in
accordance with National / Local Codes covering installation.
Maximum water supply pressure 550 kPa (80psi).
Tank max capacity - 40ltrs of water.
Input Rating (N.H.G.C.) 46 MJ/hr 47 MJ/hr 47 MJ/hr
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 0.92 kPa 2.6 kPa 2.6 kPa
Gas Connection ¾BSP Male