19
- NAT Gas / LPG / Butane Only.
NOTE: Gas regulator supplied is
convertible between Natural
Gas and LP Gas, but it’s outlet
pressure is fixed ex-factory and
is NOT to be adjusted.
On completion of gas conversion, replace gas type labels located at:-
- Rear of unit, above gas connection.
- Beside rating plate.
Before leaving installation;
1. Check all gas connections for leakage using soapy water or other gas detecting equipment.
2. Carry out a ‘Commissioning’ check of appliance as shown in Installation Section of this manual.
3. Ensure any adjustments done to components that have adjustments / settings paint sealed are to be
re-sealed.
NOTE: If for some reason it is not possible to get appliance to operate correctly, shut ‘Off’ gas
supply and contact supplier of this appliance.
NOTE, Pin rotated
for Natural Gas
NOTE, Pin rotated
for LPG
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.