20
- Australia
- New Zealand:
- United Kingdom & EU (CE):
Category: II
2H3P
(20. 37), II
2H3B/P
.(20, 28-30).
Flue Type: A
1.
NOTE: (*) Measure burner operating pressure at upper test point (Supply Pressure) on gas control
valve located behind control panel, this is to be carried out with burner operating at High
Flamesetting. Operating pressure is ex-factory set, through appliance regulator and not to
be adjusted, apart from when carrying out gas conversion, if required. Refer to Gas
Conversion and SpecificationSection for further details.
Main Burner Injectors Ø 3.10mm Ø 1.90mm
Pilot Burner Injectors
0.62 0.35
Low Fire Screw Ø 1.55mm Ø 1.55mm
High Fire Screw
Fully Out (c.c.w.) Fully Out (c.c.w.)
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.92 kPa 2.6 kPa
Gas Regulator Cap Screw
Main Burner Injectors Ø 3.10mm Ø 1.80mm
Pilot Burner Injectors
0.62 0.35
Low Fire Screw Ø 1.55mm Ø 1.55mm
High Fire Screw
Fully Out (c.c.w.) Fully Out (c.c.w.)
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.92 kPa 2.6 kPa
Gas Regulator Cap Screw
Main Burner Injectors Ø 3.10mm Ø 1.90mm
Pilot Burner Injectors
0.62 0.35
Low Fire Screw Ø 1.55mm Ø 1.55mm
High Fire Screw
Fully Out (c.c.w.) Fully Out (c.c.w.)
Supply Pressure
20 mbar 37 mbar
Burner Operating Pressure
9.5 mbar 27.7 mbar
Gas Regulator Cap Screw
Loading ...
Loading ...
Loading ...