Waldorf PCB8140G Bold 450mm Gas Pasta Cooker

Installation Operation Manual - Page 5

For PCB8140G.

PDF File Manual, 25 pages, Read Online | Download pdf file

PCB8140G photo
Loading ...
Loading ...
Loading ...
3
PC[1]8140G GAS PASTA COOKER (Single Tank - 40 Ltr)
NOTE:
[1]: - Model Options;
- - Standard.
L - Low Back.
B - Bold Front.
LB - Low Back & Bold Front.
A commercial heavy duty, gas fired high performance Pasta Cooker designed for pasta cooking
commercial high production output, using LPG (Propane) or Natural Gas. The boiling medium is
contained within a heavy gauge stainless steel tank, heated by one infra red surface burner from
beneath the tank.
This Pasta Cooker features an Over Temperature Safety Cut Out System with Full Flame Failure Safe-
ty Controls.
An open tank design to make cleaning a simple and easy task.
This appliance can be fitted with the following optional accessories, (refer to the 'Replacement Parts
List' for details).
Plinth Kit.
Basket 1/4, 165 x 165mm.
Basket 1/4, 165 x 165mm.
Basket 1/2, 320 x 165mm.
- Australia:
- New Zealand:
- UK Only:
Category: II
2H3P.
Flue Type: A
1.
NOTE: (*) Measure burner operating pressure at upper test point (Supply Pressure) on gas control valve
located behind control panel, this is to be carried out with burner operating at High Flame
setting. Refer to Gas Conversion and SpecificationSection for further details.
Input Rating (N.H.G.C.) 46 MJ/hr 47 MJ/hr
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 0.92 kPa 2.6 kPa
Gas Connection ¾BSP Male
Input Rating (N.H.G.C.) 46 MJ/hr 47 MJ/hr
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 0.92 kPa 2.6 kPa
Gas Connection ¾BSP Male
Nominal Reduced Pilot Nominal Reduced Pilot
Heat Input (nett) 12.0 kW 5.4 kW 320W 12.5 kW 6.2 kW 320W
Gas Rate 1.27 m
3
/hr 0.42 m
3
/hr 0.03 kg/hr 0.97 kg/hr 0.48 kg/hr 0.02 kg/hr
Supply Pressure 20 mbar 37 mbar
Burner Operating Pressure (*) 27.7 mbar 9.5 mbar
Gas Connection
3
/
4
BSP Male
Loading ...