21
- All Other Markets:
(*) NOTE:
(*) Burner operating pressure is to be measured at Burner Operating Pressure test
point on gas control valve, with burner operating at 'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be
adjusted, apart from when converting between gasses, if required.
Standard models can only be converted between Nat. Gas, LP Gas and Butane, but not
Town Gas.
Refer to Gas Conversion and Specifications' section in this manual for further details.
Main Burner Injectors Ø 3.10mm Ø 1.80mm Ø 1.70mm
Pilot Burner Injectors
0.62 0.35 0.35
Low Fire Screw
Ø 1.55mm
2 turns out (c.c.w.)
Ø 1.55mm
Fully In (c.w.)
Ø 1.55mm
Fully In (c.w.)
High Fire Screw
Fully Out (c.c.w.) Fully Out (c.c.w.) Fully Out (c.c.w.)
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.92 kPa 2.6 kPa 2.6 kPa
Gas Regulator Cap Screw