Specifications
4
- All Other Markets:
 (*) Measure burner operating pressure at target top hob manifold test point with target
top burner (Inner and outer ring) operating at full setting.
 NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be
adjusted, apart from when converting between gasses, if required.
 (**) TOWN GAS Only - Burner operating pressure is to be adjusted using adjustable gas
regulator supplied. Town Gas Option is only available with specific ex-factory built
Town Gas models, which can also be converted to any other gas. Standard models can
only be converted between Nat. Gas, LP Gas and Butane, but not Town Gas.
 Refer to ‘Gas Conversion and Specifications' section of this manual for further details.
Gas Connection
Bench Models
Gas supply connection point is located 130mm from right hand side of appliance, 32mm from rear,
55mm from floor and is entered from beneath appliance. An optional underside connection is
available.
All Other Models:
Gas supply connection point is located 130mm from right hand side of appliance, 32mm from rear,
655mm from floor and is entered from beneath appliance. An optional underside connection is
available.
Connection is ¾” BSP male.
For Refrigeration Cabinet Specifications refer to Refrigeration Cabinet Installation and Operation
Manual supplied with appliance.
Natural Gas Town Gas (**)
Input Rating (N.H.G.C.) 45 MJ/hr 45 MJ/hr
Supply Pressure 1.13 - 3.40 kPa 0.75 - 1.50 kPa
Burner Operating Pressure (*) 1.0 kPa 0.63 kPa
Gas Connection ¾” BSP Male
LP Gas (Propane) Butane
Input Rating (N.H.G.C.) 45 MJ/hr 45 MJ/hr
Supply Pressure 2.75 - 4.50 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 2.6 kPa 2.6 kPa
Gas Connection ¾” BSP Male