Blue Seal Evolution G57-B Series 900mm Gas Target Top Bench Model

Installation Operation Manual - Page 25

For G57-B.

PDF File Manual, 29 pages, Read Online | Download pdf file

G57-B photo
Loading ...
Loading ...
Loading ...
Gas Conversion and Specifications
23
- United Kingdom:
Category: II
2H3P.
Flue Type: A
1.
(*) Measure Burner operating pressure at target top hob manifold test point with target top
burner (Inner and Outer ring) operating at full setting. Operating pressure is ex-factory set,
through appliance regulator and is not to be adjusted, apart from when carrying out gas
conversion, if required. (Refer to details in ’Gas Conversion’ section for information).
Natural Gas (G20) Propane (G31)
Main Burner Injector (Inner Ring) Ø 1.70mm Ø 1.10mm
Main Burner Injector (Outer Ring) Ø 2.60mm Ø 1.55mm
Pilot Burner Injector 0.35 0.25
Burner Aeration Screw X (Inner) 25mm 20mm
Burner Aeration Screw Y (Outer) 28mm 25mm
Low Fire Adjustment 2½ turns out (ccw) 1¾ turn out (ccw)
Burner Operating Pressure (*) 9.9 mbar (*) 26.8 mbar (*)
Gas Regulator Cap Screw