Blue Seal Evolution G57-B Series 900mm Gas Target Top Bench Model

Installation Operation Manual - Page 11

For G57-B.

PDF File Manual, 29 pages, Read Online | Download pdf file

G57-B photo
Loading ...
Loading ...
Loading ...
Installation
9
Installation Requirements
NOTE:
 It is most important that this Target Top is installed correctly and that operation is correct
before use. Installation shall comply with local gas and health and safety requirements.
 This appliance shall be installed with sufficient ventilation to prevent occurrence of
unacceptable concentrations of health harmful substances in the room, the appliance is
installed in.
Blue Seal Target Tops are designed to provide years of satisfactory service, and correct installation is
essential to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in
accordance with relevant National / Local codes covering gas, electrical and fire safety.
AUSTRALIA: - AS5601 - Gas Installations.
NEW ZEALAND: - NZS5261 - Gas Installation.
UNITED KINGDOM: - Gas Safety (Installation & Use) Regulations 1998.
- BS6173 - Installation of Catering Appliances.
- BS5440 1 & 2 - Installation Flueing & Ventilation.
- BS7671 - Requirements for Electrical Installation.
IRELAND: - IS 820 - Non - Domestic Gas Installations.
Installation must be carried out by qualified persons only. Failure to install equipment to
relevant codes and manufacturer’s specifications shown in this section will void the warranty.
Components having adjustments protected (e.g. paint sealed) by the manufacturer are only
to be adjusted by an authorised service agent. They are not to be adjusted by the installation
person.
Unpacking
 Remove all packaging and transit protection from appliance including all protective plastic coating
from exterior stainless steel panels.
 Check equipment and parts for damage. Report any damage immediately to carrier and distributor.
 Ensure all 4 adjustable feet are fitted with the protruding centre screw. (Not fitted on G57 - RB
Models).
 Report any deficiencies to distributor who supplied appliance.
 Check available gas supply is correct to as shown on rating plate. Refer to ‘Dimensions’ section for
rating plate locations for different models.
Location
1. Installation must allow for sufficient flow of fresh air for combustion air supply.
2. Installation must include adequate ventilation means, to prevent dangerous build up of combustion
products.
3. Never directly connect a ventilation system to appliance flue outlet.
4. Any gas burning appliance requires adequate clearance and ventilation for optimum and trouble-free
operation. Minimum installation clearances shown overleaf are to be adhered to.
5. Position target top in its approximate working position.
6. All air for burner combustion is supplied from beneath appliance. Legs must always be fitted and no
obstructions placed on underside or around base of appliance, as obstructions will cause incorrect
operation and / or failure of appliance.
NOTE: Do not obstruct or block appliances flue. Never directly connect a ventilation system to
appliance flue outlet.
Combustion Air Requirements:
Natural Gas 12 m
3
/hr
LPG / Butane 12 m
3
/hr
Town Gas 12 m
3
/hr
Loading ...
Loading ...
Loading ...