Gas Conversion and Specifications
24
- All Other Markets:
NOTE:
 (*) Measure burner operating pressure at target top hob manifold test point with target
top burner (Inner and outer ring) operating at full setting.
 NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be
adjusted, apart from when converting between gasses, if required.
 (**) TOWN GAS Only - Burner operating pressure is to be adjusted using adjustable gas
regulator supplied. Town Gas Option is only available with specific ex-factory built
Town Gas models, which can also be converted to any other gas. Standard models can
only be converted between Nat. Gas, LP Gas and Butane, but not Town Gas.
 Refer to the information in this section for further details.
Natural Gas Town Gas (**)
Main Burner Injector (Inner Ring) Ø 1.70mm Ø 4.20mm
Main Burner Injector (Outer Ring) Ø 2.60mm Ø 6.30mm
Pilot Injector 0.35 0.70
Burner Aeration Screw X (Inner) 25mm 20mm
Burner Aeration Screw Y (Outer) 28mm 25mm
Low Fire Adjustment 2
1
/
2
turns out (ccw)
Blank
1½ turns out (ccw)
Burner Operating Pressure (*) 1.0 kPa (*) 0.63 kPa (*)
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to the Burner
Operating Pressure
specified)
LP Gas (Propane) Butane
Main Burner Injector (Inner Ring) Ø 1.10mm Ø 1.00mm
Main Burner Injector (Outer Ring) Ø 1.55mm Ø 1.45mm
Pilot Injector 0.25
Burner Aeration Screw X (Inner) 25mm
Burner Aeration Screw Y (Outer) 28mm
Low Fire Adjustment 1 turn out (ccw)
Burner Operating Pressure (*) 2.6 kPa (*)
Gas Regulator Cap Screw