IPSO DR445 21kg Stacked Dryer

Original Instructions - Page 82

For DR445.

PDF File Manual, 108 pages, Read Online | Download pdf file

DR445 photo
Loading ...
Loading ...
Loading ...
© Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
Operating Instructions
70458301ENR6
80
Topoffs
Any time the control receives a coin drop pulse during
a cycle it will add the programmed dry time to the time
currently remaining in the cycle. The maximum cycle
time is 99 minutes, the control will not add time
beyond 99 minutes. The cool down time will not
change.
If the control receives a coin drop pulse during cool
down the IN USE LED will flash briefly to indicate the
coin input, the machine will exit cool down and it will
start heating. The cycle time will be equal to the
programmed dry time.
Temperature Selector Switch
For five minutes after the control is powered up, there
is a diagnostic feature that allows the temperature
selector switches to be tested.
When the temperature selector is changed, the new
setting is displayed by flashing the IN USE LED as
follows:
High/Normal: 4 flashes
Medium/PP: 3 flashes
Low/Delicate: 2 flashes
No Heat: 1 flash
NOTE: To change dipswitch settings refer to Single
Drop Timer Section.
To Program a Short Test Cycle:
1. Unplug machine power cord.
2. Write down machine control dip switch settings,
then set them all to the off position. Refer to
Figure 42.
3. Plug machine in and start a cycle.
NOTE: With all control dip switches off, the total
cycle time will be 2 minutes long (1 minute of heat
and 1 minute of cool down).
4. Once all testing is complete, unplug machine and
re-set dip switches to their original settings.
5. Plug machine in.
Figure 42
Error Codes
TMB2216N
1 2 3 4 5 6 7 8O
N
1
2345
6
78
Display Definition Corrective Action
AF (flashing)
Airflow switch opened/closed 5 or more
times in a running cycle.
Check airflow switch. Replace if inoperative.
Loading ...
Loading ...
Loading ...