IPSO DR445 21kg Stacked Dryer

Original Instructions - Page 15

For DR445.

PDF File Manual, 108 pages, Read Online | Download pdf file

DR445 photo
Loading ...
Loading ...
Loading ...
© Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
13
70458301ENR6
Specifications and Dimensions
NOTE: All machines are shipped with extra nipple
to convert to metric thread (from Standard).
Specifications 025 Series 030 Series 035 Series 055 Series
Noise level measured during
operation at operator position of
3.3 feet (1 meter) in front of machine
and 5.2 feet (1.6 meters) from floor
60 dBA 61 dBA 63 dBA 63 dBA
Net Weight (approximate):
Pounds (kg )
300
(137)
330
(150)
360
(163)
435
(197)
Standard Packaging Weight:
Pounds (kg )
332
(151)
364
(165)
394
(179)
476
(216)
Standard Packaging Shipping
Dimensions:
Inch (mm)
30 x 43 x 69
(762 x 1,092 x
1,753)
30 x 49 x 69
(762 x 1,245 x
1,753)
33 x 49 x 69
(838 x 1,245 x
1,753)
35.5 x 59 x 72
(902 x 1,499 x
1,829)
Slat Crate Packaging Weight:
Pounds (kg )
406
(184)
446
(202)
480
(218)
506
(230)
Slat Crate Shipping Dimensions:
Inch (mm)
34.5 x 46 x 87.75
(876 x 1,168 x
2,229)
34.5 x 52 x 87.75
(876 x 1,321 x
2,229)
37.5 x 52 x 87.75
(953 x 1,321 x
2,229)
40 x 60 x 87.25
(1,016 x 1,524 x
2,216)
Cylinder Size:
Inch (mm)
26.5 x 24
(673 x 610)
26.5 x 30
(673 x 762)
30 x 30
(762 x 762)
33 x 35
(838 x 889)
Cylinder Capacity (dry weight):
Pounds (kg )
25
(11.3)
30
(13.6)
35
(15.9)
55
(24.9)
Drive Motor:
Horsepower (kW)
1/4
(0.1865)
1/4
(0.1865)
1/4
(0.1865)
Nonreversing
1/2 (0.373)
Reversing
1/4 (0.1865)
Fan Motor:
Horsepower (kW)
1/4
(0.1865)
1/4
(0.1865)
1/4
(0.1865)
1/2
(0.373)
Maximum Airflow per
Pocket: C.F.M. (l/sec)
50 Hertz 430
(203)
430
(203)
550
(260)
600
(283)
60 Hertz 500
(236)
500
(236)
650
(307)
700
(330)
Maximum Static Back
Pressure:
Inch W.C. (mbar, kPa)
50 Hertz 0.6
(1.5, 0.15)
0.6
(1.5, 0.15)
0.5
(1.3, 0.13)
0.5
(1.3, 0.13)
60 Hertz 0.8
(2.0, 0.2)
0.8
(2.0, 0.2)
0.6
(1.5, 0.15)
0.6
(1.5, 0.15)
Gas Models
Gas Connection 1/2 in. NPT 1/2 in. NPT 1/2 in. NPT 1/2 in. NPT
Gas Burner Rating:
Btu/hr. (kW, Mj/hr.)
50 Hertz 64,000
(18.7, 67.5)
73,000
(21.4, 77)
90,000
(26.4, 95)
102,000
(29.9, 107.6)
60 Hertz 64,000
(18.7, 67.5)
73,000
(21.4, 77)
90,000
(26.4, 95)
112,000
(32.8, 118.2)
Electric Models
Heating Element Rating:
400/50/3 10 kW
21 kW 24 kW 27 kW
Standard 12 kW
Steam Models
Steam Connection 3/4 in. NPT 3/4 in. NPT 3/4 in. NPT N/A
Steam Coil Rating at 100 psig:
Boiler Horsepower (Btu/hr.)
(recommended operating
pressure 80-100 psig)
3.9
(134,700)
3.9
(134,700)
4.8
(166,000)
N/A
N/A = Not Applicable
Loading ...