IPSO DR445 21kg Stacked Dryer

Original Instructions - Page 50

For DR445.

PDF File Manual, 108 pages, Read Online | Download pdf file

DR445 photo
Loading ...
Loading ...
Loading ...
70458301ENR6
48
© Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
Gas Requirements
IMPORTANT: Any product revisions or conversions
must be made by the Manufacturer’s Authorized
Dealers, Distributors or local service personnel.
IMPORTANT: The tumble dryer must be isolated
from the gas supply piping system by closing its
individual manual shut-off valve during any
pressure testing of the gas supply piping system at
test pressure equal to or less than
0.5 psig
(34.5 mbar, 3.45 kPa).
NOTE: For gas valves with a manual shut-off
switch on the gas valve, the shut-off switch does not
protect the valve from this pressure test. Use the
individual manual shut-off valve from the gas
supply piping system to protect the gas valve.
IMPORTANT: The tumble dryer and its manually
operated appliance gas valve must be disconnected
from the gas supply piping system during any
pressure testing of that system at test pressures in
excess of
0.5 psig (34.5 mbar, 3.45 kPa).
IMPORTANT: The installation must comply with
local codes or, in the absence of local codes:
with the latest edition of the “National Fuel
Gas Code,” ANSI Z223.1/NFPA 54 in the
U.S.A.
with CAN/CSA-B149.1 or Natural Gas and
Propane Installation Code in Canada
In Australia and New Zealand
, installation
must comply with the Gas Installations
Standard AS/NZS 5601 Part 1: General
Installations.
Obtain specific gas service pipe size from the gas
supplier. Refer to Table 5 for general pipe size.
The following must be furnished and installed by the
customer for the gas service line to each tumble dryer.
Refer to Figure 21.
Sediment traps
Shut-off valves
Supply pressure taps
It is important that equal pressure be maintained at all
tumble dryer gas connections. This can be done by
installing a 1 inch (25.4 mm) pipe gas loop to maintain
equal pressure at all gas connections. Refer to
Figure 22.
WARNING
To reduce the risk of fire or explosion, DO
NOT CONNECT THE GAS LINE TO THE
TUMBLE DRYER IF THE GAS SERVICE IS
NOT THE SAME AS THAT SPECIFIED ON
THE TUMBLE DRYER SERIAL PLATE! It
will first be necessary to convert the gas
burner orifice and gas valve. Appropriate
conversion kits are available.
W060R1
To reduce the risk of gas leaks, fire or
explosion, use a new flexible stainless
steel connector.
W774
WARNING
To reduce the risk of fire or explosion, if
the tumble dryer is to be connected to
Liquefied Petroleum (L.P.) gas, a vent to
the outdoors must be provided in the
room where the tumble dryer is installed.
W062R1
Loading ...
Loading ...
Loading ...