Karcher 1.509-500.2 STATIONARY HIGH PRESSURE UNIT HDC Standard

User Manual - Page 22

For 1.509-500.2.

PDF File Manual, 328 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
- 8
You can enter into a maintenance contract with the con-
cerned Kaercher Sales Office for the machine.
The machine should be stored in frost-free rooms. In
case there is frosting risk, for e.g. if the machine is in-
stalled in open areas, then the machine must first be
emptied and flushed using an anti-freezing agent.
Screw off water supply hose and high pressure
hose.
Operate device for max. 1 minute until the pump
and conduits are empty.
Note: Observe handling instructions of the anti-freeze
agent manufacturer.
Fill in normal anti-frost agents in the swimmer tank
right until the top.
Place the collection trough under the high pressure
exit.
Switch on the appliance and let it run until the safe-
ty mechanism against lack of water in swimmer
tank gets activated and the machine is switched
off.
A certain corrosion protection is achieved with this as
well.
Transport
CAUTION
Risk of injury and damage! Observe the weight of the appliance when you transport it.
When transporting in vehicles, secure the appliance according to the guidelines from slipping and tipping over.
Storage
CAUTION
Risk of injury and damage! Note the weight of the appliance in case of storage.
Care and maintenance
DANGER
Risk of injury! The main switch is to be switched off while carrying out any repairs or maintenance jobs.
Maintenance schedule
Time Activity Assembly affected Performance of whom
daily Check hand-spray
gun
Hand spray gun Check whether the hand-spray gun closes tightly without any
leaks. Check the protection mechanism against accidental
switching. Replace defective hand-spray guns.
Operator
Check high pressure
hoses
Outlets, hoses towards working machine Check hoses to see if there are damages. Replace defect hos-
es immediately. Danger of accident!
Operator
weekly or after 40 operat-
ing hours
Check the unit for
leaks
Entire plant Check pumps, overflow valve and pipe system for leaks. Inform
Customer Service if there is oil below the pump or if there is a
leakage of more than 3 drops of water per minute. Keep the
leakage borings clear.
Operator/Cus-
tomer service
Check oil level Oil level indicator on the pump If the oil is milky, it needs to be replaced. Operator
Check oil level Oil level indicator on the pump Check oil level of the pump. Refill oil if required (Order no.
6.288-016)
Operator
monthly or after 200 oper-
ating hours
Check pump High-pressure pump Check the pump for leaks. If the leakage is more than 3 drops
per minute, call Customer Service.
Operator
Check water scarcity
fuse
Swimmer switch in the swimmer tank Press the swimmer of the low water fuse down for about 5 sec-
onds and control the error indicator on the control board. Re-
move deposits if necessary.
Operator
Test swimmer valve Float tank The water level must be 40 mm below the overflow. No water
must exit while the swimmer valve is closed.
Operator
Check overpump
time.
Controls Close consumer loads (e.g. hand spray guns). The pump must
switch off after the afterrun period.
Operator
Test automatic start Pressure sensor The pump stands still as there is no water transfer. Open the
hand spray gun. If the pressure in the high-pressure cycle falls
below the switchpoint, the pump must switch on.
Operator
Tighten hose clips All hose clips Tighten the hose clips using a torque wrench. Tightening torque
up to a diameter of 28 mm = 2Nm, from 29 mm = 6 Nm.
Operator
half-yearly or after 500 op-
erating hours
Oil change High-pressure pump Drain off oil. Fill in 1 l of fresh oil (order no. 6.288-016.0). Check
the oil level at the oil level indicator.
Operator
half-yearly or after 1000
operating hours
Check the appliance
for calcium deposits
entire water system Improper functioning of valves or pumps can be an indication of
calcium deposits. If necessary decalcify.
Operator trained
in decalcification
Tighten clamps Control board Tighten all clamps for components in the main circuit. Electrician
Test swimmer valve Float tank The water level must be 40 mm below the overflow. No water
must exit while the swimmer valve is closed.
Customer Ser-
vice
annual Safety check Entire plant Safety check according to the guidelines for fluid spraying
equipment.
Technical expert
Maintenance contract
Frost protection
Drain water
Flush device with anti-freeze agent
22 EN