- 5
DANGER
Risk of injury! Device, tubes, high pressure hose and
connections must be in faultless condition. If they are
not in a perfect state then the appliance must not be
used.
The operator must use the appliance correctly. When
working with the appliance, he must consider the local
conditions and pay due care and attention to other per-
sons, in particular children, who are nearby.
Never leave the appliance unattended when it is in op-
eration.
DANGER
Danger of scalding by hot water! Do not direct the
water jet on persons or animals.
Risk of burns on account of hot surfaces! Do not
touch uninsulated pipes and hoses when hot water
operations are on. Hold the jet pipe only at the han-
dles.
Risk of poisoning or itching on account of deter-
gent! Follow the given instructions for using deter-
gents. Store detergents safely and protect them
against access by unauthorised persons.
DANGER
Risk to life on account of electric shock! Do not direct
the water jet on the following equipment:
Electrical appliances and plants,
the unit itself,
all electricity-carrying parts in the working area.
There is a recoil pressure arising from the water jet that
comes out from the spray pipe. The angular spray pipe
brings about an upward force.
DANGER
Risk of injury! The recoil pressure of the spray pipe
can throw you off-balance. You may fall. The spray
jet can fly off and cause damage to persons.
Search a secure place to stand and hold the gun
firmly. Never hold on tightly to the lever of the hand
spray gun.
The jet must not be directed at other persons or di-
rected by the user at him/herself to clean clothing
or footwear.
Risk of injury from parts flying off! Flying-off frag-
ments or objects can injure people or animals. Nev-
er direct the water jet on fragile or loose objects.
Risk of accident on account of damage! Clean
tyres and valves from a minimum distance of 30
cm.
DANGER
Danger from substances that are harmful to health! Do
not spray the following materials as they can swirl up
substances that are harmful to health:
Materials containing asbestos,
Materials that could contain substances harmful to
health.
DANGER
Risk of injury on account of the emanating water jet
that could be hot! Only original Kaercher high pres-
sure hoses are optimally suited for the plant. No
guarantee can be given if you use any other hoses.
Detergents can prove to be a health hazard! If any
detergents are added, the water let out of the plant
is not of potable quality.
Risk of hearing impairment while working on noise-
making parts! If so, wear ear plugs.
WARNING
Long hours of using the appliance can cause circulation
problems in the hands on account of vibrations.
It is not possible to specify a generally valid operation
time, since this depends on several factors:
Proneness to blood circulation deficiencies (cold,
numb fingers).
Low ambient temperature. Wear warm gloves to
protect hands.
A firm grip impedes blood circulation.
Continuous operation is worse than an operation
interrupted by pauses.
In case of regular, long-term operation of the device and
in case of repeated occurrence of the symptoms (e.g.
cold, numb fingers) please consult a physician.
A Manometer
B Unlocking (START) button/readiness indicator
(green)
C STOP button/ERROR button, fault indicator light
(yellow)
When faults are triggered, the fault indicator light
lights up yellow, see "Display (in the control cabi-
net)".
The fault indicator light (yellow) of the ERROR but-
ton lights up as long as a fault exists or has been
eliminated and has not yet been deleted.
If all faults (causes) have been eliminated, the fault
message can be deleted by pressing the unlocking
button (green).
DANGER
Danger - electrical voltage!
The switch cabinet may only be opened by a qualified
electrician.
Note: The text is shown in English.
A LCD display
B Change value (-) or move cursor to the left
C Change value (+) or move cursor to the right
D Acknowledgment button (OK)
E Cancel (ESC)
When the system is ready to operate, the current
operating hours of the high pressure pumps are
shown alternating with the operating pressure.
When errors are triggered, these are shown on the
display as well (see "Help with errors").
DANGER
Risk of injury on account of the emanating water jet that
could be hot!
DANGER
Check the high pressure hose for damage before every
use. Please arrange for the immediate replacement of a
damaged high pressure hose.
Check high pressure hose, pipe connections, fit-
tings and water jet for damage every time before
use.
Check hose coupling to ensure that it sits firmly and
is leak-proof.
Turn the main switch to position “0”.
Shut off water supply.
Activate trigger gun until device is pressure-less.
Open the water supply.
Turn the main switch to position “1”.
Press the unlocking (START) button (lights up
green).
Perform the cleaning operation.
Note:If the cleaning break exceeds the set delay time
(min. 30 seconds), the appliance will stop. At the same
time, a 6-hour operation readiness period will be start-
ed. Within this operation readiness period, the appli-
ance will automatically switch on because of the drop in
pressure when the hand spray gun is opened.
Press the unlocking (START) button (lights up
green).
Press the STOP button. The unlocking button goes
out.
Turn the main switch to position “0”.
Shut off water supply.
Activate trigger gun until device is pressure-less.
Secure the hand spray gun using the safety catch
so that it doesn't open accidentally.
If the appliance is not to be used for a longer period or
if it is not possible to install it in a frost-free environment,
you must take the following measures (see chapter
"Maintenance and care", section "Anti-freeze protec-
tion"):
Drain water.
Flush device with anti-freeze agent.
Switch off the main switch and secure it.
Start up
Operation
Safety instructions
!
Machine vibrations
Control panel (in front panel)
Display (in the control cabinet)
Making the plant ready for operations
A B C
A
B C D E
Switch-off in case of emergency
Turning on the Appliance
Getting the system ready for operations
Turn off the appliance
Shutdown