Karcher 1.509-500.2 STATIONARY HIGH PRESSURE UNIT HDC Standard

User Manual - Page 20

For 1.509-500.2.

PDF File Manual, 328 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
- 6
Technical specifications
HDC 40/8
(2.509-605.0)
HDC 40/8 H
(2.509-606.0)
HDC 60/8
(2.509-611.0)
HDC 60/8 H
(2.509-612.0)
HDC 80/8
(2.509-619.0)
HDC 80/8 H
(2.509-620.0)
Performance data
Working pressure MPa (bar) 8 (80) 8 (80) 8 (80) 8 (80) 8 (80) 8 (80)
Max. excess operating pressure
(safety valve)
MPa (bar) 13 (130) 13 (130) 13 (130) 13 (130) 13 (130) 13 (130)
Flow rate l/h (l/min) 4000 (66.6) 4000 (66.6) 6000 (100) 6000 (100) 8000 (133.3) 8000 (133.3)
Water connection
Min. feed volume l/h (l/min) 4000 (66.6) 4000 (66.6) 6000 (100) 6000 (100) 8000 (133.3) 8000 (133.3)
Feed pressure (min.) MPa (bar) 0.15 (1.5) 0.15 (1.5) 0.15 (1.5) 0.15 (1.5) 0.15 (1.5) 0.15 (1.5)
Max. feed pressure MPa (bar) 0.6 (6) 0.6 (6) 0.6 (6) 0.6 (6) 0.6 (6) 0.6 (6)
Max. feed temperature °C 60 85 60 85 60 85
Electrical connection
Current type --3~3~3~3~3~3~
Frequency Hz 50 50 50 50 50 50
Voltage V 400 400 400 400 400 400
Connected load kW 14 15 19.5 21.5 27 28
Electrical protection (slow) A 32 32 50 50 63 63
Type of protection -- IPX5 IPX5 IPX5 IPX5 IPX5 IPX5
Protective class--IIIIII
Maximum allowed net impedance Ohm 0.273+j0.171 0.273+j0.171 0.248+j0.156 0.248+j0.156 0.223+j0.140 0.223+j0.140
Power supply mm
2
4x 16 4x 16 4x 16 4x 16 4x 16 4x 16
Dimensions and weights
Length mm 1168 1168 1168 1168 1168 1168
Width mm 800 800 800 800 800 800
Height mm 1469 1469 1881 1881 1881 1881
Typical operating weight kg 318.7 310.6 439.4 459.4 453.2 473.2
Values determined as per EN 60335-2-79
Noise emission
Sound pressure level L
pA
dB(A)747476767676
Uncertainty K
pA
dB(A)111111
Hand-arm vibration value
Hand spray gun m/s
2
3.63 3.63 3.63 3.63 3.63 3.63
Spray lance m/s
2
7.52 7.52 7.52 7.52 7.52 7.52
Uncertainty K m/s
2
1.01.01.01.01.01.0
Exception according to Regulation (EU) 2019/1781 Annex I Section 2 (12): a)
HDC 40/16
(2.509-603.0)
HDC 40/16 H
(2.509-604.0)
HDC 60/16
(2.509-609.0)
HDC 60/16 H
(2.509-610.0)
HDC 80/16
(2.509-617.0)
HDC 80/16 H
(2.509-618.0)
Performance data
Working pressure MPa (bar) 16 (160) 16 (160) 16 (160) 16 (160) 16 (160) 16 (160)
Max. excess operating pressure
(safety valve)
MPa (bar) 20 (200) 20 (200) 20 (200) 20 (200) 20 (200) 20 (200)
Flow rate l/h (l/min) 4000 (66.6) 4000 (66.6) 6000 (100) 6000 (100) 8000 (133.3) 8000 (133.3)
Water connection
Min. feed volume l/h (l/min) 4000 (66.6) 4000 (66.6) 6000 (100) 6000 (100) 8000 (133.3) 8000 (133.3)
Feed pressure (min.) MPa (bar) 0.15 (1.5) 0.15 (1.5) 0.15 (1.5) 0.15 (1.5) 0.15 (1.5) 0.15 (1.5)
Max. feed pressure MPa (bar) 0.6 (6) 0.6 (6) 0.6 (6) 0.6 (6) 0.6 (6) 0.6 (6)
Max. feed temperature °C 60 85 60 85 60 85
Electrical connection
Current type --3~3~3~3~3~3~
Frequency Hz 50 50 50 50 50 50
Voltage V 400 400 400 400 400 400
Connected load kW 22 22 34 35 45 46
Electrical protection (slow) A 50 50 80 80 100 100
Type of protection -- IPX5 IPX5 IPX5 IPX5 IPX5 IPX5
Protective class--IIIIII
Maximum allowed net impedance Ohm 0.180+j0.113 0.180+j0.113 0.158+j0.099 0.158+j0.099 0.138+j0.087 0.138+j0.087
Power supply mm
2
4x 16 4x 16 4x 35 4x 35 4x 35 4x 35
Dimensions and weights
Length mm 1168 1168 1168 1168 1168 1168
Width mm 800 800 800 800 800 800
Height mm 1469 1469 1881 1881 1881 1881
Typical operating weight kg 327.5 426.7 465.5 552.5 540.8 560.8
Values determined as per EN 60335-2-79
Noise emission
Sound pressure level L
pA
dB(A)808082828282
Uncertainty K
pA
dB(A)111111
Hand-arm vibration value
Hand spray gun m/s
2
3.63 3.63 3.63 3.63 3.63 3.63
Spray lance m/s
2
7.52 7.52 7.52 7.52 7.52 7.52
Uncertainty K m/s
2
1.01.01.01.01.01.0
Exception according to Regulation (EU) 2019/1781 Annex I Section 2 (12): a)
20 EN
Loading ...
Loading ...
Loading ...