2
We are confident that you will be delighted with your WALDORF GAS GRIDDLE RANGE ELECTRIC OVEN,
and it will become a most valued appliance in your commercial kitchen.
To ensure you receive the utmost benefit from your new Waldorf appliance, there are two important things
you can do.
Please read the instruction book carefully and follow directions given. The time taken will be well spent.
If you are unsure of any aspect of the installation, instructions or performance of your appliance,
contact your WALDORF dealer promptly. In many cases a phone call could answer your question.
These instructions are only valid if the country code appears on the appliance. If the code does not
appear on the appliance, refer to the supplier of this appliance to obtain the technical instructions for
adapting the appliance to the conditions for use in that country.
GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF
FIRE.
THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED.
IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE
CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS
OR ANY OTHER APPLIANCE.
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY
DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE.
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT
LOCATION. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER.
27
- All Other Markets:
NOTE:
Measure burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
apart from when converting between gasses, if required.
TOWN GAS Only - Burner operating pressure is to be adjusted using Town Gas adjustable
gas regulator supplied.
Refer to Gas Conversion and Specificationssection of this manual for further details.
Main Burner
GP8910GE / GEC 3.00mm 1.80mm 1.65mm 5.50mm
GP8121GE / GEC 2.85mm 1.70mm 1.55mm 5.20mm
Pilot Injector 0.41 0.25 0.25 0.75
Low Fire Adjustment 1 Full Turn Counter Clockwise from the 'Fully In' Position.
High Fire Adjustment Maximum Flow Screw. Fully In c.w.
0.90 kPa 2.6 kPa 0.63 kPa Burner Operating Pressure (*)
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa 0.75 - 1.50 kPa
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to Burner
Operating Pressure
specified)