8
NOTE:
It is most important that this appliance is installed correctly and that operation is correct
before use. Installation shall comply with local gas, electrical and health and safety
requirements.
This appliance shall be installed with sufficient ventilation to prevent occurrence of
unacceptable concentrations of health harmful substances in the room, the appliance is
installed in.
Waldorf Gas Griddle Range Electric Oven are designed to provide years of satisfactory service and correct
installation is essential to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in
accordance with relevant National / Local codes covering gas, electrical, fire safety and health and safety.
Australia: - AS5601 - Gas Installations.
New Zealand: - NZS5261 - Gas Installation.
Australia / New Zealand: - AS / NZS3000 - Wiring Rules.
United Kingdom: - Gas Safety (Installation & Use) Regulations 1998.
- BS6173 - Installation of Catering Appliances.
- BS5440 1 & 2 - Installation Flueing & Ventilation.
- BS7671 - Requirements for Electrical Installations.
Ireland: - IS 820 - Non - Domestic Gas Installations.
Installations must be carried out by qualified persons only. Failure to install equipment to the
relevant codes and manufacturers specifications shown in this section will void the warranty.
Components having adjustments protected (e.g. paint sealed) by the manufacturer are only
to be adjusted by an authorised service agent. They are not to be adjusted by the installation
person.
Remove all packaging and transit protection from appliance including all protective plastic coating
from exterior stainless steel panels.
Check equipment and parts for damage. Report any damage immediately to carrier and distributor.
Ensure the 4 adjustable feet with the protruding centre screw are fitted.
Report any deficiencies to distributor who supplied appliance.
Check available gas supply is correct to as shown on rating plate located on front right hand corner
of bottom sill.
1. Installation must allow for sufficient flow of fresh air for combustion air supply.
2. Installation must include adequate ventilation means, to prevent dangerous build up of combustion
products.
3. Never directly connect a ventilation system to appliance flue outlet.
4. Position appliance in its approximate working position.
5. All air for burner combustion is supplied from underneath unit. Legs must always be fitted and no
obstructions placed on underside or around base of appliance, as obstructions will cause incorrect
operation and / or failure of appliance.
6. Components having adjustments protected (e.g. paint sealed) by manufacturer are only to be
adjusted by an authorised service agent. They are not to be adjusted by installation person.
NOTE: Do not obstruct or block appliances flue. Never directly connect a ventilation system to
appliance flue outlet.
Combustion Air Requirements:
GP8910GE / GEC GP8121GE / GEC
Natural Gas 19 m
3
/hr 26 m
3
/hr
LP Gas / Butane 20 m
3
/hr 27 m
3
/hr
Town Gas 19 m
3
/hr 26 m
3
/hr