Bosch VGD553FR0/02 Serie 4 Gas oven

User Manual - Page 22

For VGD553FR0/02.

PDF File Manual, 56 pages, Read Online | Download pdf file

VGD553FR0/02 photo
Loading ...
Loading ...
Loading ...
en Installation instructions
22
17.5 Installation in a tall unit
Observe the installation dimensions and the safety clearances in a tall unit.
¡ Ensure that the intermediate floor has a gap to the
installation wall in order to ventilate the appliance.
¡ If the tall unit has another back panel in addition to
the element back panels, this must be removed.
¡ Only fit the appliance up to a height which allows
accessories to be easily removed.
17.6 Installing two appliances on top of
each other
Your appliance can also be installed above another ap-
pliance.
17.7 Guidelines for the ventilation
Only install this appliance in a room that has sufficient
ventilation.
¡ If the total power of all gas appliances is below
11kW, this requirement is met if the installation
room has a volume of more than 15m³ and at least
one door leads outdoors or one window leads out-
doors.
¡ If the total power of all gas appliances is above
11kW, this requirement is met if the installation
room has a volume of more than 2m³ per kW and
at least one door leads outdoors or one window
leads outdoors.
Furthermore, an extractor hood or controlled do-
mestic ventilation without air recirculation is present
and a minimum flow rate of 15m³/h per kW total
power is possible for all gas appliances.
Ensure that suitable ventilation openings are avail-
able.
Note:In some countries, the requirements for minimum
room volume vary. Find out information on this from
customer service.
17.8 Electrical connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
¡ The fuse protection must correspond to the power
rating specified on the appliance's rating plate and
to local regulations.
¡ The appliance corresponds to protection class I and
must only be operated with a protective earth con-
nection.
¡ The appliance must be disconnected from the
power supply whenever installation work is being
carried out.