GE - General Electric GPF400A Dishwasher Door and Access Color Panels

User Manual - Page 9

For GPF400A.

PDF File Manual, 32 pages, Download pdf file

Loading ...
Loading ...
Loading ...
9
FOR PERSONAL SAFETY:
REMOVE HOUSE FUSE OR
OPEN CIRCUIT BREAKER
BEFORE BEGINNING
INSTALLATION.
DO NOT USE AN EXTENSION CORD OR ADAPTER
PLUG WITH THIS APPLIANCE. FOLLOW NATIONAL
ELECTRICAL CODES OR PREVAILING LOCAL CODES
AND ORDINANCES.
Power
Supply
Electrical Requirements:
These dishwashers must be supplied with a
120 volt, 60 Hz power supply with an indi-
vidual, properly grounded branch circuit,
protected by a 15 or 20 amp fuse or circuit
breaker or time delay fuse.
A side-by-side dual dishwasher installation
requires two separate circuits.
Wiring must be 2 wire with ground.
If electrical supply does not meet the above
requirements, call a licensed electrician
before proceeding.
Grounding Instructions:
This appliance must be either connected to a
grounded-metal permanent wiring system, or
an equipment-grounding conductor must be
run with the circuit conductors and be
connected to the equipment-grounding
terminal or lead on the appliance.
Double
Dishwashers
THE IMPROPER CONNECTION OF
THE EQUIPMENT - GROUNDING
CONDUCTOR CAN RESULT IN A
RISK OF ELECTRIC SHOCK. CHECK
WITH A QUALIFIED ELECTRICIAN
OR SERVICE REPRESENTATIVE IF
When installing two dishwashers side-by-side,
place electrical supply for each dishwasher as
shown in diagram for single dishwasher
installation.
A side-by-side dual installation requires two
separate circuits.
WARNING
WARNING
YOU ARE IN DOUBT WHETHER THE APPLIANCE IS
PROPERLY GROUNDED.
Installation Preparation
CleanSensor Dishwasher
Cabinet Preparation & Wiring:
Wiring may enter from either side, the rear,
or from the floor within the shaded area
shown.
Cut hole 1-1/2" max. dia. within the shaded
area to admit the electrical cable or power
cord. The hole must be free of sharp edges.
If the cabinet wall partition is metal, the
edge of the hole must be covered with a
rubber protector.
Electrical Connections:
The electrical connection is on the right side
of the dishwasher.
For cable direct connections, the cable must
be routed as illustrated. The cable must
extend forward a minimum of 24" from the
rear wall.
For power cord connections, install a 3-
prong type receptacle in the rear wall of sink
cabinet next to the dishwasher. Install the
receptacle at least 6" and not more than 18"
from the opening and off the floor.
Allow approximately 3" between cable and
adjacent cabinetry.
5"
White
18"
6"
5"
4"
4"
24"
from Wall
3"
from
Cabinet
Alternate
Receptacle
Location
Ground
Black
1-1/2" Dia. Hole (Max.)
18"
6"
6"
Receptacle
Location
Area
Toe
Space
Electrical Supply For 2-Dishwasher Installation
5"
4"
5"
5"
4"
5"
4"
6"
48" Min.
24"
Loading ...
Loading ...