Installation
www.bora.com
54321
6
5
1
Abb. 6.18 Securing the cooktop in the middle
[1] Cooktop
[2] Suction opening
[3] Air inlet nozzle
[4] Stainless steel grease filter
[5] Worktop cut-out
[6] Mounting bracket
For surface mounting
Make sure that the sealing tape for the cooktop is flat
against the worktop.
For flush installation
Make sure that the sealing tape of the cooktop is
sealed well all the way round.
If applicable, insert the height adjustment plate.
Fasten the cooktop to the worktop using the mounting
brackets [6].
Next, insert the stainless steel grease filter [4] and the
air inlet nozzle [3].
Seal the surrounding gap with black, heat-resistant
silicone sealant.
click
1
4
3
2
Abb. 6.16 Mounting the frame of the exible duct
[1] Retaining groove of the housing of the activated charcoal
filter
[2] Position shackles
[3] Flexible duct frame
[4] Lower lock
Insert the frame of the flexible duct into the retaining
groove on the housing of the activated charcoal filter
[1].
Ensure that both lateral position shackles [2] are in the
guide.
Slide the frame upward [3] until the lower [4] and
upper lock engage in the middle.
Ensure that the frame is inserted into the housing
groove [1] all round.
1
2
Abb. 6.17 Inserting the activated charcoal lter
[1] Housing cover of the activated charcoal filter
[2] Activated charcoal filter
Remove the packaging from the activated charcoal
filters.
Insert the two activated charcoal filters [2] from below.
Check the direction of flow of the filters.
This is identified by an arrow.
Close the housing cover [1].