III.2.b ASPIRATION INSTALLATION
The base of the kitchen must be drilled as indicated in Fig. 3.2.b.1 if the space available to
house the hood is less than 560mm the back need to be removed.
The installation of the appliance implies a maximum length of the drawers that may be
mounted under the hob (Fig. 3.2.b.2-A; Fig. 3.2.b.2-B):
Upper drawers depth approximately 470mm Drawers depth approximately 470mm
Last drawer depth approximately 320mm
The depths of the drawers are approximate and generated by the project of a kitchen base unit
with standard dimensions.
Fig. 3.2.b.1
Fig. 3.2.b.2-A
Fig. 3.2.b.2-B