en Installation instructions
44
isolating switch must be integrated into the perman-
ent electrical installation in accordance with the in-
stallation regulations.
Electrically connecting an appliance without a
protective contact plug
Note:Only a licensed professional may connect the ap-
pliance. Damage caused by incorrect connection is not
covered under the warranty.
An all-pole isolating switch must be integrated into the
permanent electrical installation according to the install-
ation regulations.
1.
Identify the phase and neutral conductors in the
socket.
The appliance may be damaged if it is not connec-
ted correctly.
2.
Connect the hob in accordance with the connection
diagram.
See the rating plate for the voltage.
3.
Connect the wires of the mains power cable accord-
ing to the colour coding:
Green/yellow = Protective conductor ⁠
Blue = Neutral conductor
Brown = Phase (external conductor)
25.8 Installing the appliance
Note:Do not use a cordless screwdriver to secure the
panels. This may damage the panels.
1.
Push the appliance in fully.
Do not kink or trap the connection cable, or route it
over sharp edges.
2.
Centre the appliance.
There must be an air gap of at least 4mm between
the appliance and adjacent unit fronts.
3.
Open the appliance door and unscrew the left and
right-hand panels.
4.
Close the appliance door.
5.
Screw the appliance into place.
6.
For handleless kitchens with vertical bar handle
strips:
Attach a suitable filling piece ⁠ in order to cover
any sharp edges and to guarantee a safe install-
ation.
Pre-drill aluminium profiles to establish a screw
connection ⁠.
Secure the appliance using a suitable screw ⁠.
7.
Refit the panels and screw them in place, first at the
top and then at the bottom.