Table 9: Optional Zone Controllers for Mega 115 HXV Systems (see page 14 for Functions, Controls and Options).
Before specifying or placing an order, refer to the V-Net Network Solution Engineering Product Data Book and review the detailed technical data provided to fully understand the capabilities / limitations of these devices.
Zone Controller Name Model No. Case Color
Max Wire
Length (ft)
Description
Simple Controller
with mode selection
PQRCVCL0Q Black
164
Allows control of indoor unit on/off, operation mode, fan speed,
and temperature setpoint for up to 16 indoor units.
PQRCVCL0QW White
Simple Controller
without mode
selection
PQRCHCA0Q Black
164
Allows control of indoor unit on/off, fan speed, and temperature
setpoint for up to 16 indoor units.
PQRCHCA0QW White
LG Premium
Controller
PREMTA000 Ivory 164
Allows control of indoor unit on/off, operation mode, occupied/
unoccupied temperature setpoints, fan speed, and air flow
direction for up to 16 indoor units. Programmable schedule with
5 events per day with control of occupied/unoccupied, on/
off, mode, setpoints and fan speed. Advanced functions
include two setpoint autochangeover, minimum difference
between setpoints, setback, timed override, target energy
consumption display, check energy display and master/slave.
LG Programmable
Thermostat
PREMTB10U White 164
Allows control of indoor unit on/off, operation mode, occupied
and unoccupied temperature setpoints, fan speed, and airflow
direction for up to 16 indoor units. Programmable schedule
with 5 events per day with control of occupied/unoccupied, on/
off, mode, setpoints and fan speed. Advanced functions include
two setpoint auto changeover, minimum difference between
setpoints, setback and timed override.
Table 10: Zone Controller Communication Cables.
Communication Cable Name Model No. Wire Length (ft) Description
Wired Remote/Group Control
Extension Cable
PZCWRC1 33
Increases the distance between a remote controller and an
indoor unit or between indoor units in a control group.
Table 11: Speciality Application Devices for Mega 115V HXV Systems (see page 14 for Functions, Controls and Options)..
Speciality Application
Device
Name Model No.
Connect
to
Application
Binary
Signals Input/
Output
Description
Simple Dry Contact PQDSB1
Indoor
Unit
On/Off, Run Status,
Error Status
1/2
Enables the indoor unit to be
controlled and monitored by third
party controls using binary inputs
and outputs.
Dry Contact Unit for
Economizer, occupied/
unoccupied
PQDSBC1
On/Off, Mode,
Controller Lock, Power
Save, Run Status,
Error Status
2/2
Dry Contact Unit for 24V
Thermostat
PDRYCB300
On/Off, Thermo On/
Off, Mode, Fan Speed,
Run Status, Error
Status
---
Enables the indoor unit to be
controlled and monitored by a
third party thermostat or
controller.