Bora PURSU S Pure Induction Cooktop with Integrated Cooktop Extractor - Recirculation

User Manual - Page 22

For PURSU.

PDF File Manual, 72 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
EN
98
Appliance description
www.bora.com
5.2.6 Sounds
i
The volume of the acoustic signals can be set
in the menu (0% to 100%).
i
The acoustic signal for the power button
cannot be set to 0.
i
Safety-relevant acoustic signals are always
emitted with the volume at 100%.
The system basically differentiates between two
different types of acoustic signals:
Acoustic signal Purpose
Short individual beep (0.1 s)
Confirmation of a selection
Sequence of beeps Interaction required
Tab. 5.5 Sounds
5.3 How the cooktop
extractor works
Depending on the model you purchased, the
cooktop extractor can be operated as an exhaust air
or a recirculating air version.
Exhaust air mode
The air suctioned away is purified by the grease filter
and expelled into the open air via a duct system.
The exhaust air must not be expelled into:
O
a smoke or exhaust gas flue that is in operation
O
a shaft used for the aeration of rooms where
fireplaces are installed.
If the exhaust air is to be directed into a smoke or
exhaust gas flue that is not in use, the installation
must be checked and approved by the responsible
heating engineer.
5.2.4 7-segment display
Multi-function display Meaning
Fan display
 – 
Power levels
Power setting
Inactive
Automatic extractor function
Automatic after-run
Filter service
Multi-function
display
Time indication
Error code
Cooking zone indicator Meaning
Cooking zone
indicator
 – 
Power level
Power setting
Heat retention level
Coffee function
Pan size recognition
Inactive
Residual heat indicator
(cooking zone is switched
off but still hot)
Error
Tab. 5.3 Meaning of the 7-segment displays
5.2.5 Lighting
i
The operating panel has 2 different levels of
lighting (100% and 50%).
i
On principle the system adapts the lighting
to the current operating scenario. Relevant
display elements are more brightly lit and
irrelevant ones are dimmed. Unavailable
functions are faded out.
Lighting Use
100% Function is active and selected
50%
Function is inactive but can be selected
0%
(no indicator)
Function is unavailable
Tab. 5.4 Lighting
Loading ...
Loading ...