1. Install a manual gas line shut-off valve in the gas line
in an easily accessed location outside of the range.
Make sure everyone operating the range knows where
and how to shut off the gas supply to the range.
2. Install male W' flare union adapter to the W' NPT
internal thread elbow at inlet of pressure regulator. Qn
models equipped with standard twin burners, install the
male pipe thread end of the 1/2"flare union adapter to
the 1A" NPT internal thread at inlet of pressure
regulator. Use a back-up wrench on the regulator fitting
to avoid damage..
When installing the range from the front, remove the 90 °
elbow for easier installation_
3. Install male 1/2"or 3A"flare union adapter to the NPT
internal thread of the manual shut-off valve, taking care
to back up the shut-off valve to keep it from turning.
4. Connect flexible metal appliance connector to the
adapter on the range. Position range to permit
connection at the shut-off valve.
5. When all connections have been made, make sure all
range controls are in the off position and turn on the
main gas supply valve_ Use a liquid leak detector at all
joints and connections to check for leaks in the system..
CAUTION: DoNOTUSEAFLAMETo
CHECKFORGASLEAKS.
]
When using test pressures greater than 1/_psig to
pressure test the gas supply system of the residence,
disconnect the range and individual shut-off valve from
the gas supply piping. When using test pressures of _A
psig or less to test the gas supply system, simply isolate
the range from the gas supply system by closing the
individual shut-off valve.
STEP 3
Electrical Connections
(on some models)
Electrical Requirements
120-volt, 60 Hertz, properly grounded branch circuit
protected by a 15-amp or 20-amp circuit breaker or time
delay fuse..
Extension Cord Cautions
Because of potential safety hazards associated with
certain conditions, we strongly recommend against the
use of an extension cord.. However, if you still elect to use
an extension cord, it is absolutely necessary that it be a
UL-listed, 3-wire grounding-type appliance extension cord
and that the current carrying rating of the cord in
amperes be equivalent to, or greater than, the branch
circuit rating..
Grounding--.IMPORTANT (Please read carefully)
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
The power cord of this
appliance is equipped
with a three-prong
(grounding) plug which
mates with a standard
three-prong grounding
wall receptacle to
minimize the possibility of
electric shock hazard
from this appliance..
PREFERRED
METHOD
The customer should have the wall receptacle and
circuit checked by a qualified electrician to make sure
the receptacle is properly grounded°
Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced with
a properly grounded three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR
REMOVE THE THIRD (GROUND) PRONG FROM THE
POWER CORD.