3030
ADJUSTMENT
The hobs are delivered to operate as indicated on the data plate. If a transformation
should be necessary, proceed as described in the next paragraph.
ADJUSTMENT- ADAPTING TO DIFFERENT TYPES OF GAS
Injector replacement and air adjustment for models: H30 - H360 - H380 - H39 - HF40 - HP45F
- HP65 - HP75 - HP95 - HAP95 - XLP90F- HP1230 - HP125 - HAP125 - HP665 - HP965 - HP1265 -
HP90 - HP120
1. Remove the grill and the burners from the worktop.
2. Unscrew the screws marked with the arrows that x the worktop to allow it to be raised, g.5,
g.5a, g.5b (H360 – HP95 – HP665).
3. Unscrew venture pipe screw “F” (g. 6, g. 7) and open completely the air regulator “R” .
4. Unscrew the injectors (U) and replace them with those suitable for the gas in use and supplied
with the appliance. Refer to table 1 on page 17.
5. Air adjustment is made by the special regulator “R” based on the “X” values shown in table 1, on
page 19, opening of primary air. When adjustment is over block the regulator “R” with screw “F”.