36
W415-0748 / 12.12.08
7.2.1 Optional Front Removal
Pull on the top of the optional front away from the
replace until the male portion of the latch
disengages. Tilt forward slightly and lift from the 4
shoulder screws (if installed).
7.2.2 Control Panel Removal
Tilt control panel away from the door and lift from
slots.
7.2.3 Turn Power and Gas off to the unit.
7.2.4 Door Removal. See “DOOR REMOVAL” section.
7.2.5 Burner Removal
Start by removing the logs being careful since the
logs may still be warm. Remove the 2 screws holding
the air de ector then remove the 3 screws holding
the burner. Lift burner from rebox.
7.2.6 Remove the 5 screws securing the burner base. Once the gas has been disconnected, the valve train
assembly will lift out. Service components as required.
REMOVE 4 SCREWS
BLOWER
MOUNTING PLATE
REMOVE 2 SCREWS
BURNER
BASE
AIR
DEFLECTOR
BURNER
7.0 SERVICING / REPLACEMENTS
7.1 BLOWER REPLACEMENT
Your comes equipped with a heat circulating blower. The blower
is pre-wired and is controlled by the remote control supplied with the unit.
Drywall dust will penetrate into the blower bearings, causing irreparable
damage. Care must be taken to prevent drywall dust from coming into contact
with the blower or its compartment. Any damage resulting from this condition
is not covered by the warranty policy.
7.1.1 Turn off the power to the replace.
7.1.2 Turn off the gas valve.
7.1.3 Remove the glass door, logs, rear log supports, brick panels, air
de ector, burner assembly, panel support, panel support bracket.
7.1.4 The blower mounting plate can now be removed. Remove the four
screws that secure the plate to the rebox base.
7.1.5 The blower is secured to the rebox. Disconnect the wire connectors
before attempting to remove the blower from the rebox.
7.1.6 Remove the two screws securing the blower and lift through blower
access opening.
NOTE: When re-installing the replacement blower, it will be necessary
to replace the gasket (W290-0104) on the blower mounting plate.
7.2 BURNER AND VALVE REPLACEMENT
FIGURE 7.1.4
FIGURE 7.1.6
FIGURE 7.2.5
FIGURE 7.2.6
!
WARNING
Risk of fire and electrical shock.
Turn off the gas and electrical power before servicing this fireplace.
!
WARNING
Be careful not to tear the burner train gasket. A replacement gasket can be ordered from your local
authorized dealer.