Majestic WDV600PTSC Wall Mountable Direct Vent Liquid Propane Fireplace

User Manual - Page 9

For WDV600PTSC.

PDF File Manual, 52 pages, Read Online | Download pdf file

WDV600PTSC photo
Loading ...
Loading ...
Loading ...
78D0011
9
WDV Series Gas Fireplace
The replace must be secured to the oor and/or to framing
studs as shown in Figure 6. Use two (2) wood screws or
masonry/ concrete screws to secure replace to the oor.
Use four (4) screws to attach replace to framing. The side
nailing anges are 1/2" or 5/8" to accommodate different
wall thickness.


    


: Any remote wiring (i.e. remote control, wall switch,
and optional fan) must be done prior to nal nishing to
avoid costly reconstruction.
Only noncombustible materials (i.e. brick, tile, slate, steel,
or other materials with a UL re rating of Zero) may be
used to cover the black painted face of the appliance. It is
permissible to bring combustible wall board to the top of
the standoffs on the top and to the wall board stand-offs
on the sides of the unit. A 300°F minimum adhesive may
be used to attach facing materials to the black surface. If
joints between the nished wall and the replace surround
are sealed, a 300°F minimum sealant material (General
Electric RTV103 or equivalent) must be used.
 Fireplace may be installed on top of framing or
platform constructed of combustible materials which do
not protrude beyond the face.
6”
Framing Members
Nailing Flange
FP2430
Figure 6 -
Secure Fireplace to Framing Studs
Nailing Flange
Nailing Flange
Screws
Screws
Noncombustible Material