Majestic WDV600PTSC Wall Mountable Direct Vent Liquid Propane Fireplace

User Manual - Page 10

For WDV600PTSC.

PDF File Manual, 52 pages, Read Online | Download pdf file

WDV600PTSC photo
Loading ...
Loading ...
Loading ...
10
78D0011
WDV Series Gas Fireplace

Consult local building codes before beginning the
installation. The installer must make sure to select the
proper vent system for installation. The approved 5 x
8 venting components are Duravent and Selkirk
products listed on Page 49. UL1777 exible venting
is also approved for use on these models. Before
installing vent kit, the installer must read this replace
manual and vent kit instructions.
Only a qualied installer/service person should install
venting system. The installer must follow these safety
rules:
Wear gloves and safety glasses for protec-
tion.
Use extreme caution when using ladders or
when on rooftops.
Be aware of electrical wiring locations in walls
and ceilings.
The following actions will void the warranty on your vent-
ing system:
Installation of any damaged venting component.
Unauthorized modication of the venting system.
Installation of any component part not manufactured
or approved by Vermont Castings Group.
Installation other than permitted by these instruc-
tions.


   






Figure 7 -
Combustible Clearances for Vent Pipe
12" Vertical Rise
Required Before
Horizontal Run
FP2424








     


  



until the ue penetrates the outside wall. 
      
      
     Z\x   


* A minimum of 3" clearance to the top is
required along horizontal length until ue
pipe penetrates outside wall.
** A minimum 1" clearance to combustibles
permitted all around ue at outside wall