Ensure that the wall socket is located in the hatched
area
⁠ or outside of the installation space.
Secure any unsecured units to the wall using a stand-
ard bracket ⁠.
21.4 Installation below a worktop
Observe the installation dimensions and the safety
clearances when installing below a worktop.
To ventilate the appliance, the intermediate floor must
have a ventilation cut-out.
The worktop must be secured to the fitted unit.
21.5 Installing below a hob
If the appliance is installed below a hob, the following
minimum dimensions must be adhered to (including
substructure, if applicable).
The required minimum worktop thickness ⁠ is based
on the required minimum clearance
⁠.
Hob type ⁠ raised in
mm
⁠ flush in
mm
⁠ in
mm
Induction hob 48 49 5
Full-surface in-
duction hob
58 59 5
Observe the installation instructions for the hob.
Note:Not suitable for installing under a gas hob or
electric hob.
21.6 Installation in a tall unit
Observe the installation dimensions and the safety
clearances in a tall unit.
To ventilate the appliance, the intermediate floor must
have a ventilation cut-out.
If the tall unit has another back panel in addition to the
element back panels, this must be removed.
Do not fit the appliance too high up; it must be pos-
sible for accessories to be removed easily.
21.7 Combination with a warming drawer
First fit the warming drawer. Follow the installation in-
structions for the warming drawer.
Slide the appliance, on the warming drawer, into the fit-
ted cabinet. When sliding in the appliance, do not dam-
age the warming drawer's panel.
21.8 Corner installation
Observe the installation dimensions and the safety
clearances when installing in a corner.