Loading ...
Loading ...
Loading ...
MODEL NAME CLIMATE PRO X26
Electronic Features Control Programmable
Cooling Capacity
Rating Conditions: 95°F, 60% RH
24,000 Btu/h
Electrical
Characteristics
Voltage Requirement 208/230V, 1Phase, 60Hz
Total Power Consumption 2.7 kW
Current Consumption 12.4 amps
Recommended Fuse Size 20 amps
NEMA Plug Confi guration 6-20
Min. - Max. Voltage 198 -253
Fans Motor Output 0.56 kW
Evaporator
Fan Type Centrifugal
Max. Air Flow (hi/mid/low) 700/650/595 CFM
Max. External Static Pressure
0.42 IWG
Condenser
Fan Type Centrifugal
Max. Air Flow (hi/mid/low) 1475/1370/1260 CFM
Max. External Static Pressure
0.25 IWG
Compressor
Type Hermetic Rotary
Output 1.5 kW
Refrigerant Type R-410A
Dimensions W x D x H 22 x 29 x 51 in
Weight Net / Shipping 216/256 lb
Power Cord
Gauge 12 AWG (3-core)
Length 6 
Condensate Tank Capacity 5 gal
Operating Conditions
Min. 70°F (@ 50% RH)
Max. 113°F (@ 50% RH)
Max. Duct Length
Per Cold Duct Hose 60 
Hot Duct Hose 45 
Max. Sound Level
With Duct (hi/mid/low) 66/65/64 dB(A)
Without Duct (hi/mid/low) 69/68/67 dB(A)
77
TECHNICAL SPECIFICATIONS
Specifi cations are subject to change without notice.
Loading ...
Loading ...
Loading ...