PLUGGING IN THE UNIT
Check the power supply outlet rating, recommended fuse size, and NEMA plug confi guration below.
MODEL
MINIMUM POWER SUPPLY RATING RECOMMENDED FUSE SIZE
NEMA PLUG
CONFIGURATION
Climate Pro X14 115V, 1 phase, 60 Hz, 15A 15A maximum 5-15
Climate Pro X20 115V, 1 phase, 60 Hz, 20A 20A maximum 5-20
Climate Pro X26 208/230V, 1 phase, 60 Hz, 20A 20A maximum 6-20
WARNING
Insert the power plug properly into the outlet. Incomplete insertion may cause fi re or electric
shock.
To avoid fi re, electric shock or malfunction:
Do not connect or disconnect the power plug with wet or oily hands.
Do not turn the unit on or o by connecting or disconnecting the power plug.
To avoid generation of heat, fi re or electric shock:
Do not use an extension cord or multi-socket plug.
Do not heat, pull, wind, bundle or place heavy objects on the power cord.
Do not use damaged power cord/plug or modify the cord/plug.
Qualifi ed personnel must replace the damaged power cords with one of the same LCDI
(Leakage Current Detection Interrupter) cord, obtainable from the AC manufacturer.
Incorrect replacements may cause fi re, electric shock, injury or malfunction.
Always use fuses with correct capacity. Using copper or other wire may result in fi re or
malfunction.