3. Installer’s Guide
Gas Connection
The cooker is provided with a rating plate placed on the rear panel near the gas inlet, showing the type of gas
and pressure for which the appliance has been originally adjusted.
Before connecting this appliance, check if it is prepared for the type of gas and pressure available in the home.
If not, it is necessary to convert the appliance to another gas type as indicated in the Tables section.
This appliance is suitable for connection to Natural and Universal LPG (ULPG). Refer to gas pressure shown on
the data plate and in the Tables section.
The appliance must be connected to the gas supply or the cylinder, according to Australian Standards.
The gas connection is male 1/2” BSP and is situated 55mm from the right and 550mm from the oor. There are
two ways to connect to the main gas line:
A. The Cooker can be connected with rigid pipe as specied in AS/NZS 5601 table 3.1.
The cooker must be installed securely and level.
Use the leg accessories
A
.
You will require an assistant to lift one side of the unit.
Never invert the unit.
Screw leg at corner holes below unit one at a time
B
.
You will require an assistant to lift the other side of the unit. Screw
the other two legs the same way before at different corners.
Adjust height of leg by turning lower portion clockwise or counter-
clockwise
C
.
NOTE: Unit must be level.