Scandium SCU900CR 90cm Freestanding Dual Fuel Oven/Stove

User Manual - Page 12

For SCU900CR.

PDF File Manual, 36 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
Page 12
3. Installer’s Guide
Conversion to Other Type of Gas
This operation must be executed by qualied and authorised personnel.
This appliance has been designed to function with ULPG or Natural gas.
This appliance is provided with a label on the rear panel, near the gas inlet, indicating the type of gas and
pressure for which the cooker has been adjusted.
The indication of the gas and pressure that the cooker has been adjusted to can also be found on the data
label or on the package of the appliance. Choose Inlet gas connection according to the type of gas available
in your home.
1. To adapt the appliance to a gas different from that for which it was set up proceed as follows:
1.1 remove the grids
1.2 remove the burners caps and burner heads
1.3 with a 7mm socket spanner unscrew and remove the injectors.
1.4 replace the injectors with those supplied corresponding to the gas available (see burner and injector
characteristics in the Tables section)
1.5 replace the various parts proceeding in reverse.
2. Move the air regulator which is input to the burner near the injector to increase or decrease the air
passage.
3. The ame on the small output is regulated in the factory. When the injectors have been replaced or there
are special mains pressure conditions, it may be necessary to regulate the minimum again. The operations
necessary to perform this operation are the following:
3.1 Light the burner on and put the knob to the Low Position.
3.2 In this position, remove the knob of the tap.
3.3 With a screw driver adjust the tap screw until the ame is conveniently regulated
to the low position and stable
3.4 Reassemble the knob and pass quickly from the Full On Position to the Low Position,
several times, to ensure that the ame remains stable.
3.5 For burners with a safety valve make sure that the regulation obtained is sufcient to
maintain heating of the thermocouple. If it is not, increase the minimum.
After connecting the unit, check for gas leaks with soap and water solution, NEVER USE A FLAME.
Place, near the inlet gas connection, a label indicating the type of gas for which the appliance is now
prepared. “Appliance prepared for...“
When converting from Natural Gas to Propane ensure that the NG regulator is removed and replaced with
the Test Point Assembly. A gas regulator suitable for a supply pressure of 2.7kPa should be part of the gas
tank supply and the test point pressure should be adjusted to 2.75kPa. Replace the old data plate with one
that is suitable for the type of gas for which the appliance has been converted.