Electrical Connections
Dual Voltage Motors
Models 113.196321 and 113.196421 ONLY!
To Change Motor Voltage to 240 A.C.
Under normal home workshop conditions, if
full voltage is supplied to the motor, your
saw will operate efficiently on 120V. If any
of the following conditions exist, it will be
advisable to have a qualified electrician
reconnect the motor for 240V operation:
heavy duty operation
either undersized or overloaded branch
circuit serves the saw
power company cannot correct a low volt-
age situation.
The following procedure to change motor
voltage should be performed only by a quali-
fied electrician. Note: Whenever changing
the switch position from 120 to 240V,, make
certain that all necessary steps (inch_ding
proper fusing of the branch circuit) are com-
pleted.
1. Unplug saw.
2. Remove pan head screw from top of
motor cov_'r. Remove motor cover panel at
blade end of motor.
3. Use sma!l screwdriver to slide dual volt-
age switch to 240V position.
4. Re-install motor cover panel.
5. Replace 120V power cord plug with
240V, 15 amp, 3-prong plug.
6. Connect power cord white and black leads
to two "hot" plug blades; connect power
cord grounding wire to plug ground prong.
7. Plug cord into 240V, 15 amp, 3-blade
receptacle. Make sure receptacle is connect-
ed to a 240V A.C. power supply through a
240V branch circuit having at least a 15 amp
time delay fuse or circuit breaker. Note: No
adapter is available for thi_ O'pe plug.
DANGER
To avoid electric shock, unplug saw
before changing motor voltage.
Pan Head
Screw
Motor Cover
Panel
Dual Voltage
Switch
44