Before you call for service...
Troubleshooting -tips
Problem Possible Causes What To Do
Salty tasting or Unit not sanitized • Conq)lete the Sanitizing Procedures on page 12.
brown/yellow colored • At ('(nnl)ledon of recharge cycle (approx. '2h_,O, run water
waterafter installation ti'om timcets to purge the salty water:
Low water pressure Check pI'esstlI'e,
• Drain height 8' or less, pressure shotfld be minimum of 20 psi.
• Drain height above 8', pressure should be minimum ot 50 psi.
Restricted drain hose • Clean and reconnect hose.
• Check fin" ]6nks in drain line.
Brown/yellow Unit was idle for a period of time • Complete the Sanitizing Procedureson page 12.
colored water
Resin beads showing Cracked distributor " Call fin" se_i('e.
up in drinking water
and sink
Sounds you might hear Rmmhag water from the unit • This is IlOIIllal.
into a drain durhag rechmge
Water has air bubbles Air ha system after installation " _'_]11go away alter it runs fin" a while.
and is cloudy
Error Code on control Wiring may have worked loose " See page 1(3fin" details.
ha the control
• Unl)lug transfin3ne_:
• Remove control cove_; release clips on side.
• Check fin" loose/incorrect wiring connections to electronic
board or swit('h. Reconnect as required.
• Reassemble control cove_:
• Plug in Transfin3ne_:
• X_'ait six minutes fin" Error Code to real)pea_;
• If Error Code reappeaI_, call fin" service.
Blue light flashing
When power applied Control needs to be pmgrmnmed • See the Programming the Controlsection, page 9-10.
to the system (a power outage may have occurred)
If "DAYS TOEMPTY" Low salt level, less thma 15 days • Ell with salt.
is flashing • Reset salt level.
If "Err"in display Electrical problem with system • See page 16 fin" details.
• See l)rocedtlre above, EITOI" code oi1 control.