Due to our policy of continuous product innovation, some specications may change without notication.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
PRODUCT DATA | 11
Product Data
GENERAL DATA / SPECIFICATIONS
Table 2: Vertical Air Handling Unit General Data.
Type Vertical Air Handling Unit
System (Model) (Indoor Unit / Outdoor
Unit)
LV180HV4
(LVN180HV4/
LUU188HV)
LV240HV4
(LVN240HV4/
LUU248HV)
LV360HV4
(LVN360HV4/
LUU368HV)
LV420HV
(LVN420HV/
LUU428HV)
LV480HV
(LVN480HV/
LUU488HV)
Cooling Capacity (Min/Rated/Max)
(Btu/h)
8,000 ~ 18,000 ~
24,000
9,000 ~ 24,000 ~
28,000
14,000 ~ 36,000 ~
44,000
17,000 ~ 42,000 ~
48,000
18,000 ~ 48,000 ~
53,000
Cooling Power Input
1
(kW) 0.65 ~ 1.35 ~ 2.70 0.70 ~ 1.92 ~ 3.20 1.25 ~ 2.88 ~ 4.80 1.35 ~ 3.80 ~ 5.30 1.40 ~ 4.80 ~ 6.00
EER 13.33 12.50 12.50 11.05 10.00
SEER 19.0 18.0 18.0 17.0 16.5
Heating Capacity (Min/Rated/Max)
(Btu/h)
9,000 ~ 20,000 ~
23,000
10,000 ~ 27,000 ~
30,000
15,000 ~ 40,000 ~
47,000
18,000 ~ 47,000 ~
55,000
19,000 ~ 56,000 ~
60,000
Heating Power Input
1
(kW) 0.65 ~ 1.60 ~ 2.10 0.75 ~ 2.26 ~ 2.80 1.35 ~ 3.39 ~ 5.05 1.45 ~ 4.00 ~ 5.65 1.50 ~ 5.10 ~ 6.20
COP 3.66 3.50 3.46 3.44 3.22
HSPF 9.5 10.0 10.0 10.0 9.5
Maximum Heating Capacity (Btu/h)
Outdoor 17°F) (WB)/Indoor 70°F (DB) 18,000 22,000 32,000 37,000 40,000
Outdoor 5°F(WB)/Indoor 70°F (DB) 16,000 20,000 30,000 32,000 34,000
Power Input [W] @ Outdoor 5°F (WB) 2,500 3,200 4,400 4,800 5,250
Outdoor -4 °F(WB)/Indoor 70°F (DB) 11,000 15,000 22,000 24,000 26,000
Power Supply V, Ø, Hz 208-230 / 1 / 60
Outdoor Unit Operating Range
Cooling (°F DB) 5 - 118
Optional Wind Bafe Cooling (°F DB) Yes (-4)
Heating (°F WB) -4 - 64 -4 - 64 -4 - 64 -4 - 64 -4 - 64
Indoor Unit Operating Range
Cooling (°F WB) 57 - 77
Heating (°F DB) 59 - 81
Indoor Temperature Setting Range
Cooling (°F DB) 65 - 86
Heating (°F WB) 61 - 86
EEV: Electronic Expansion Valve, IDU: Indoor Unit, ODU: Outdoor Unit. This unit comes
with a dry helium charge.
This data is rated 0 ft above sea level, with 24.6 ft of refrigerant line per indoor unit and a 0
ft level difference between outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor coil at 80ºF dry bulb (DB) and
67ºF wet bulb (WB); and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet
bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and
60ºF wet bulb (WB); and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet
bulb (WB).
1 Power Input is rated at high speed.
2 All communication / connection (power) cable from the outdoor unit to the indoor unit
are field supplied and is to be a minimum four-conductor, 18 AWG, stranded, shielded or
unshielded (if shielded, it must be grounded to the chassis of ODU only), and must comply
with applicable local and national codes.
3 Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or
destroy R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F)
under section 608 of CAA.
4 Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745 and
are the same in both cooling and heating mode. These values can increase due to ambient
conditions during operation.
5 Piping lengths are equivalent.