SPN FMI COMPONENT P-CODE CONDITION
DISPLAYED ON
INSTRUMENT
CLUSTER
DISPLAYED ON
DIGITAL WRENCH
DIAGNOSTIC
SOFTWARE
520207 4 P1834 Voltage Below Normal, Or Shorted
To Low Source
520207 5 P1836 Current Below Normal Or Open
Circuit
520208 3
Chassis Relay
P1614 Voltage Above Normal, Or Shorted
To High Source
520208 4 P1613 Voltage Below Normal, Or Shorted
To Low Source
520208 5 P1611 Current Below Normal Or Open
Circuit
520209 2
Oxygen Sensor
Heater 1
P0135 Data Erratic, Intermittent Or Incorrect
520209 3 Voltage Above Normal, Or Shorted
To High Source
520209 4 P0031 Voltage Below Normal, Or Shorted
To Low Source
520209 5 Current Below Normal Or Open
Circuit
520210 2
Oxygen Sensor
Heater 2
P0141 Data Erratic, Intermittent Or Incorrect
520210 3 P0038 Voltage Above Normal, Or Shorted
To High Source
520210 4 P0037 Voltage Below Normal, Or Shorted
To Low Source
520210 5 P0036 Current Below Normal Or Open
Circuit
520211 3
Idle Speed
P0507 Voltage Above Normal, Or Shorted
To High Source
520211 4 P0506 Voltage Below Normal, Or Shorted
To Low Source
520211 7 Mechanical System Not Responding
Or Out Of Adjustment
520268 3
Idle Air Control
M17 Stepper
Pin 3
P1519 Voltage Above Normal, Or Shorted
To High Source
520268 4 P1518 Voltage Below Normal, Or Shorted
To Low Source
126