SPN FMI COMPONENT P-CODE CONDITION
DISPLAYED ON
INSTRUMENT
CLUSTER
DISPLAYED ON
DIGITAL WRENCH
DIAGNOSTIC
SOFTWARE
523 2
Gear Sensor
Signal
P0914 Data Erratic, Intermittent Or Incorrect
523 4 P0916 Voltage Below Normal, Or Shorted
To Low Source
523 9 P1914 Abnormal Update Rate
527 31
Cruise Control
Panel Switches
P153D Condition Exists
636 2
Crankshaft
Position Sensor
P0335 Data Erratic, Intermittent Or Incorrect
637 8
Camshaft
Position Sensor
P0340 Abnormal Frequency Or Pulse Width
Or Period
651 3
Injector 1
(Front) (MAG)
(SDI Port
Injector)
P0262 Voltage Above Normal, Or Shorted
To High Source
651 4 P1262 Voltage Below Normal, Or Shorted
To Low Source
651 5 P0261 Current Below Normal Or Open
Circuit
652 3
Injector 2
(Rear) (PTO)
(SDI Port
Injector)
P0265 Voltage Above Normal, Or Shorted
To High Source
652 4 P1265 Voltage Below Normal, Or Shorted
To Low Source
652 5 P0264 Current Below Normal Or Open
Circuit
677 3
Starter
Solenoid Driver
Circuit
P0617 Voltage Above Normal, Or Shorted
To High Source
677 4 P0616 Voltage Below Normal, Or Shorted
To Low Source
677 5 P0615 Current Below Normal Or Open
Circuit
731 1
Knock Sensor 1
P0326 Data Valid But Below Normal
Operational Range - Most Severe
Level
746 3
Rear
Differential
Output (Turf)
P1692 Voltage Above Normal, Or Shorted
To High Source
746 4 P1693 Voltage Below Normal, Or Shorted
To Low Source