SPN FMI COMPONENT P-CODE CONDITION
DISPLAYED ON
INSTRUMENT
CLUSTER
DISPLAYED ON
DIGITAL WRENCH
DIAGNOSTIC
SOFTWARE
746 5 P1691 Current Below Normal Or Open
Circuit
876 3
AC Compressor
Clutch Relay
P0647 Voltage Above Normal, Or Shorted
To High Source
876 4 P0646 Voltage Below Normal, Or Shorted
To Low Source
876 5 P0645 Current Below Normal Or Open
Circuit
1071 3
Fan Relay
Driver Circuit
P1482 Voltage Above Normal, Or Shorted
To High Source
1071 4 P1483 Voltage Below Normal, Or Shorted
To Low Source
1071 5 P1481 Current Below Normal Or Open
Circuit
1127 0
Boost Pressure
Sensor
P0234 Data Valid But Above Normal
Operational Range - Most Severe
Level
1127 2 P0236 Data Erratic, Intermittent Or Incorrect
1127 3 P0238 Voltage Above Normal, Or Shorted
To High Source
1127 4 P0237 Voltage Below Normal, Or Shorted
To Low Source
1127 31 P1234 Condition Exists
1213 3
Malfunction
Indicator Lamp
P1653 Voltage Above Normal, Or Shorted
To High Source
1213 4 P1652 Voltage Below Normal, Or Shorted
To Low Source
1213 5 P1651 Current Below Normal Or Open
Circuit
1268 3
Ignition Coil
Primary Driver
1 (Front) (MAG)
P1353 Voltage Above Normal, Or Shorted
To High Source
1269 3
Ignition Coil
Primary Driver
2 (Rear) (PTO)
P1354 Voltage Above Normal, Or Shorted
To High Source