23Maintenance
DRAIN PUMP REMOVAL
INSTRUCTIONS
(FOR SERVICE ONLY)
1. Unplug the ice machine from the
electrical supply and remove the rear
access cover from the ice machine.
2. Unscrew the leveling leg in the back
corner until the end of the threaded
portion is flush with the threaded nut
insert in the base (Figure 8).
3. Unscrew the 3 hose clamps and
remove the 3 hoses from the front of
the drain pump and remove retaining
brackets (Figure 8).
4. Rotate the drain pump and remove
from the ice machine (Figure 7). It
may be necessary to disconnect the
ground wire connection in the back
flange of the cabinet (Figure 8).
Figure 8
Unscrew the leveling
leg so the end of the
threads is flush with
the top of the nut inset.
Drain pump
ground wire
connection
Remove these 3
hose clamps, then
remove the 3 tubes
from the drain pump
Figure 7
Rotate drain pump and remove from
back of ice machine.
Drain valve
Additional issues to be inspected
by the installer upon service
replacement:
1. The drain pump must be level.
2. No pinched water lines.
3. No interference with electrical cords
or wiring.
4. The drain pump should not set on
any obstacles, wiring, etc.
5. Secure all hose clamps leading to
and from the drain pump.
6. Ensure that the vent tube height is
adequate - 18 inch minimum.
7. Ensure that drain height is adequate -
maximum of 8 foot.
8. Ensure that drain length is adequate -
maximum of 20 foot.
9. Checked for water leaks after
installation of the drain pump.
10. Check for vibrations caused by
improper installation.
11. Ensure that there is no interference
with back access cover.
12. Ensure that the hole grommets are
in place at each location so that any
vent or drain tubes do not rub on any
sharp surfaces.
Figure 9
Ice Machine
Power Cord
5. Disconnect the ice machine power cord
from the drain pump (Figure 9).
6. Drain the water in the drain pump’s
reservoir by turning the pump upside
down and allowing water to drain
through the pump’s inlet and vent
tube fittings.
7. Installation of drain pump is reverse
of this procedure.