Instructions for the Installer
41
This appliance is manufactured with a green GROUND wire
connected to the oven chassis. After making sure that the power
has been turned off, connect the flexible conduit from the oven to
the junction box using a U.L. listed conduit connector. The figures
and the instructions provided below present the most common way
of connecting the ovens.
Your local codes and ordinances, of course, take precedence over
these instructions.
WARNING” Risk of Electric Shock, frame grounded to neutral of
appliance through a link.
Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and
recreational vehicles, or in an area where local codes prohibit
grounding through the neutral conductor. For installations where
grounding through the neutral conductor is prohibited:
Disconnect the ground from the neutral at free end of conduit;
Use grounding terminal or lead to ground unit; and
Connect neutral terminal or lead to branch circuit neutral in usual
manner.
3-Wire branch circuit (for US only)
Refer to the following Figure, where local codes allow the
connection of GROUND wire from the oven to the branch circuit
NEUTRAL wire (gray or white colored wire):
If local codes permit, connect the green GROUND wire from the
oven and the white wire from the oven to the branch circuit
NEUTRAL wire (gray or white colored wire).
Connect the red and black leads from the oven to the
corresponding leads in the junction box.