English-57
INSTALLATION07
Fixing the indoor unit in place
Insulation
Pipes
'X' mm
Rubber leg
'Y' mm
Perform the following work on the area where gas leak test was done priory.
Aftercheckingforgasleaksinthesystem,insulatethepipe,hoseandcables.
Then place the indoor unit on the installation plate.
1. To minimise condensation problems, wrap foam insulation (as shown in the
gure) on a part without insulation on the end of the pipes.
2. Wind the pipe, assembly cable and drain hose with vinyl tape.
3. Place the bundle (the pipe, assembly cable and drain hose) in the lower part
of the indoor unit carefully so it does not project from the rear of the indoor
unit.
4. Hook the indoor unit to the installation plate and move the unit to the right
and left until it is securely in place.
Install the outdoor unit in level on a stable base to help avoid the generation of noise and
vibration, especially when installing the unit close to a neighbor.
If you install the outdoor unit in a place exposed to strong winds or at a height, x it to an
appropriate support (wall or ground).
1. Place the outdoor unit as indicated on the top of the unit to let the discharged air
out properly.
2. Fix the outdoor unit in level to an appropriate support using anchor bolts.
3. If the outdoor unit is exposed to strong winds, install shield plates around the
outdoor unit so that the fan can operate correctly.
5. Wrap the rest of the pipe with vinyl tape.
6. Attach the pipe to the wall using clamps (optional).
Installation
plate
Connecting wires
Connecting
pipes
Vinyl tape
Drain hose
• Makesurepipedoesnotmovewhenyouinstalltheindooruniton
an installation plate.
Fixing the outdoor unit in place
Model X Y
AR09/12CWK
AR09/12DUR
602 310
AR09/12BWK
AR09/12CUR
612 317
18/24
660 340
30
690 403
• Ensurethewallwillbeabletosuspendtheweightofrackand
outdoorunit;
• Installtherackclosetothecolumnasmuchaspossible;
• Installpropergrommetinordertohelpreducenoiseandresidual
vibration transferred by outdoor unit towards wall.
Outdoor unit installed on the wall by rack
Soft rubber designed to cut off
vibration from rack to wall.
(not supplied with product)
Designed to cut off residual vibration
from outdoor unit to rack.
(not supplied with product)
• Securetherubberlegtohelppreventthegenerationofnoiseandvibration.
A3050 Australia_IB&IM_DB68-05206A_EN.indd 57 2014/12/29 19:07:43