INSTALLATION07
Installing and connecting the drain hose of the indoor unit
The drain hose must NOT
slant upwards.
The end of the drain hose
must NOT be placed under
water.
Keep a clearance of at least
5cm between the end of the
drain hose and the ground.
When installing the drain hose for the indoor unit, check if condensation draining is adequate.
Whenpassingthedrainhosethroughthe65mmholedrilledinthewall,checkthefollowings:
Drain hose installation
1. If necessary, connect the 2 meter extension drain hose to the drain hose.
2. If you use the extension drain hose, insulate the inside of the extension drain hose with a shield.
3. Fit the drain hose into 1 of 2 drain hose holes, thenx the end of the drain hose tightly with a clamp.
4. When extending the Drain Hose, hold the end of Drain Hose and Extended Hose,
rotate and insert the drain hose into Extended hose for 40~45 mm. Make sure the
two hoses are rmly connected, there is no water leakage.
5. Connect the Drain Hose after using Foam Insulation to wrap the Extended Hose. Then, Use vinyl tape to wrap the
each side of connection by 20 mm .
• Ifyoudonotusetheotherdrainhosehole,
block it with a rubber stopper.
Drain hose hole
Aftercompletingthe
installation of the drain
hose, pour water into
the drain pan to check
whether the hose is well
drained.
Wall
Indoor unit
Drain hose
The drain hose must not
be bent.
5cm
less
Do not place the end of the
drain hose in a hollow.
Ditch
•
Dont tie drain hose to the assembly pipe which may lead to water leakage.
• Ifthediameteroftheconnectionhoseissmallerthantheproduct'sdrainhose,waterleakagemayoccur.
2) Incorrect connection
Pipe
Drain hose
1) Correct connection
Pipe
Drain hose