Running at 400V3N~ (models connected accord-
ing to DIAGRAM "A"): use a five-core cable type
H05RR-F/H05RN-F (cable measuring 5 x 2.5 mm
2
).
Running at 230V3~ (models connected accord-
ing to DIAGRAM "C" but commutated by the
installer according to DIAGRAM "B"): use a four-
core cable type H05RR-F/H05RN-F (cable measur-
ing 4 x 4 mm
2
).
Running at 230V1N~ (models connected accord-
ing to DIAGRAM "C"): up to 2.9 kW use a three-
core cable type H05RR-F/H05RN-F (cable meas-
uring 3 x 1.5 mm
2
); between 2.9 kW and 5.4 kW
use a three-core cable type H05RR-F/H05RN-F
(cable measuring 3 x 2.5 mm
2
);
The end to be connected to the appliance must
have the earth wire (yellow-green) at least 20 mm
longer.
Cross-section of electrical
connecting cable
The cooker should be installed in accordance with
the latest edition of the IEE regulations.
Use a cable depending on the type of power supply
as specified in the following table.