Electrical connection
176
ATTENTION:
Before installation or servicing, dis-
connect the power supply by either
removing the fuse, manually "trip-
ping" the circuit breaker or unplug-
ging the appliance. Pull the plug not
the cord.
Installation work and repairs should
only be performed by a qualified
technician in accordance with all ap-
plicable codes and standards. Re-
pairs and service by unqualified per-
sons could be dangerous and the
manufacturer will not be held re-
sponsible. Installation, repair, and
maintenance work should only be
performed by a Miele-authorized ser-
vice technician. Work by unqualified
persons can cause considerable
danger to users. Miele cannot be
held liable for any damage arising as
a result of such work.
Before connecting the appliance to
the power supply, make sure that the
voltage and frequency listed on the
rating label correspond with the
household electrical supply. This
data must correspond to prevent ap-
pliance damage.
Consult an electrician if in doubt.
For safety reasons, the steam oven
may only be used when it has been
fully installed.
Installer:
Please leave these instructions with
the customer.
Connection
Ensure that the connection data on
the data plate (voltage, frequency,
and fuse rating) match those of your
electrical supply.
Power Supply
This appliance is equipped with a 5 ft
(1.5 m) long power cord with a NEMA
6-20P three-prong grounding plug
ready for connection.
208/240 V / 20 A / 60 Hz
Make sure that the connecting socket is
accessible after the installation of the
steam oven.
Replacing the power cord
Danger of electrical shock!
The power cord must only be re-
placed by a suitably qualified and
competent person in accordance
with current local and national safety
regulations in order to avoid a haz-
ard.
If the power cord needs to be replaced,
it must be replaced with a special con-
nection cable, type H05VV-F (PVC in-
sulated), available from Miele.