Operation
38
Place the container on the open
dishwasher door or on a surface
which is easy to clean.
Unscrew and remove the siphon.
Place the siphon on the open
dishwasher door.
Replace the empty container with a
full one.
Push the siphon into the opening of
the container and screw it on tightly.
Be sure to observe the color coding.
Wipe up any spilled neutralizing agent
thoroughly.
Place the container on the floor next
to the dishwasher or in an adjacent
cupboard. The container must be on
the same level as the dishwasher. It
must not be placed higher than the
dishwasher or on top of it.
The DOS system must then be
vented.
To vent the system and adjust the
dosage amount, see
"Settings menu, External DOS".
Checking consumption
Monitor the amount of process
chemicals used by regularly checking
the level in the container in order to
detect any dispensing irregularities.
Dispensing system maintenance
To ensure that the dispensing system
functions reliably it should be serviced
at specified intervals. This work should
only be performed by Miele Service.
The DOS module dispensing hoses
must be replaced at 1 - 1
1
/
2
yearly
intervals.
Whether you use powder or liquid
detergent, always observe the
manufacturer's instructions.
Loading ...
Loading ...
Loading ...