Loading ...
Loading ...
Loading ...
Installation
57
EN
Alternatively, it is also possible to make a
circular hole of minimum 100 mm diameter
in the non-combustible panel underneath
the appliance.
In this case, we recommend installing the
supplied gas intake extension before
positioning the appliance in the support
structure.
5.2 Gas connection
General information
This appliance is suitable for installation with
LPG or Natural Gas. Refer to “Burner and
nozzle characteristics tables” for the
relevant burner pressure and appropriate
injector sizes.
Gas leak
Danger of explosion
• After carrying out any operation, check
that the tightening torque of gas
connections is between 10 Nm and 15
Nm.
• At the end of the installation, check for
any leaks with a soapy solution, never
with a flame.
• The hoses should not come into contact
with moving parts and should not be
crushed in any way.
• Never use a naked flame to check that
gas is flowing from the burners properly,
or to look for gas leaks in the appliance.
• When hooking up the appliance to the
canister, use only the fittings and
regulators supplied with the appliance.
These products are also available from
our authorised service centres. Using
any other products can seriously
compromise the safety of the appliance.
• Do not obstruct ventilation openings of
the canister compartment.
• If operation is not optimal, DO NOT
ATTEMPT TO REPAIR THE APPLIANCE,
but contact the nearest Authorised
Service Centre.
Loading ...
Loading ...
Loading ...