Additional instructions for closet installations:
The closet door must allow for su cient air ow. Refer
to the diagram above for minimum vent opening
requirements. A louvered door is also acceptable.
Closet Door Vent Requirements
(7.6 cm)
(7.6 cm)
(2.54 cm) (2.54 cm)(68.6 cm)
14
"
max.*
(35.6
cm)
21
1
/
4
"
(54 cm)
29
1
/
2
"
(75 cm)
50
1
/
4
"
(127.5 cm)
5"**
(12.7 cm)
40
3
/
16
"
(102 cm)
CLEARANCES (continued)
Recommended installation spacing for cabinet installation:
For cabinet installation with a door, minimum ventilation
openings in the top of the cabinet are required.
*Required spacing
**For side or bottom venting,
2-inch (5.1 cm) clearance is allowed.
29 ½"
(75 cm)
7"* (17.8 cm)
7"* (17.8 cm)
5"*
(12.7 cm)
1"*
(2.5 cm)
(68.6 cm)
1"
(2.54 cm)
1"
(2.54 cm)
27
"
INSTALLATION INSTRUCTIONS